hi-mo-x6-max-explorer

Up to 630

Module Power

Up to 23.30

Module Efficiency

15 Years

Product Warranty

25 Years

Power Warranty

Core Advantages

Avoid Dust Accumulation

Short side without A side design enables dust on the module to naturally slide off under the influence of gravity and rainfall

Reliable Structure

Patented frame and advanced sealing techniques ensure durability and load capacity.

Reduce the Cost of Operation and Maintenance

The design is resistant to dust accumulation and requires less frequent cleaning, significantly reducing the number of maintenance operations
 
 
 
 

Enhanced Benefits

Noticeable gain in power generation, reducing the frequency and cost of cleaning.
 
 
 
 

FAQs

What is the product positioning of Hi-MO X6 Max Guardian series?
    • The LONGi Hi-MO X6 Max Guardian series is positioned as a "function adding series products". Currently, there are two product designs available : Hi-MO X6 Max Guardian (Anti-Dust Design) and Hi-MO X6 Max Guardian (Anti Humidity & Heat Design). More modules will be launch in the future according to market demands.
    •  
What are the models of Hi-MO X6 Max Guardian (Anti-Dust Design) series?
Hi-MO X6 Max Guardian series (Anti-Dust Design) is available in 72c and 54c. Hi-MO X6 Max Guardian series (Anti Humidity & Heat Design) is a 72c bifacial dual-glass product.
In which specific scenarios is the Hi-MO X6 Max Guardian (Anti-Dust Design) applicable?

Firstly, the Hi-MO X6 Max Guardian (Anti-Dust Design) is specifically designed for scenarios prone to dust accumulation, with a focus on: - Low roof slopes: General commercial and industrial buildings such as logistics, manufacturing, and processing have color steel tile roofs with smaller slopes, making it difficult for dust to slide off. - High dust accumulation on components: High emission industries such as chemical, non-ferrous metals, and paper manufacturing have environments with many suspended particulates, leading to significant dust accumulation on the components. - Low frequency of cleaning: Enclosed settings like research institutions, academic campuses, and breeding facilities require reduced external contact due to safety and regulatory demands, resulting in lower cleaning frequency. - High difficulty in cleaning: Functional buildings like sunrooms, photovoltaic carports, and residential rooftops either lack a roof or have roofs with low load-bearing capacity, making it challenging to perform manual cleaning. Secondly, the Hi-MO X6 Max Guardian (Anti-Dust Design) is a leading model of the Hi-MO X6 series and, aside from the above-mentioned scenarios, can be extensively used in other settings as well.

Mechanical Parameters

Layout
144(6X24)
 
 
Junction box
Split junction box, IP68

Weight

28.5kg
 
Size
2382X1134X30mm
 
Packaging

36 pcs./pallet

144 pcs./20GP

720 pcs./40HC

720 pcs./13.5m FR

1008 pcs./17.5m FR

Electrical Performance Parameters (STC Test)

Module modelLR7-72HTHF-605MLR7-72HTHF-610MLR7-72HTHF-615MLR7-72HTHF-620MLR7-72HTHF-625MLR7-72HTHF-630M
Maximum power (Pmax/W)605610615620625630
Open-circuit voltage (Voc/V)52.2752.4252.5752.7252.8753.02
Short circuit current (Isc/A)14.7414.8014.8714.9315.0115.07
Peak power voltage (Vmp/V)44.0344.1844.3344.4844.6344.78
Peak power current (Imp/A)13.7513.8113.8813.9414.0114.07

Electrical Performance Parameters (NOCT Test)

Module modelLR7-72HTHF-605MLR7-72HTHF-610MLR7-72HTHF-615MLR7-72HTHF-620MLR7-72HTHF-625MLR7-72HTHF-630M
Maximum power (Pmax/W)452.1455.9459.6463.4467.1470.8
Open-circuit voltage (Voc/V)49.1749.2249.3649.5949.6449.78
Short circuit current (Isc/A)11.9111.9512.0112.0612.1212.17
Peak power voltage (Vmp/V)40.1840.3240.4640.5940.7340.87
Peak power current (Imp/A)11.2611.3111.3611.4211.4711.52

Mechanical Load Capacity

Maximum static load on the front (such as snow and wind)
5400Pa
 

Maximum static load on the back (such as wind)

2400Pa
 
Hail test
Diameter 25 mm, impact speed 23 m/s
 

Temperature Coefficient (STC test)

Temperature coefficient of short circuit current (Isc)
+0.050%/℃
 
Temperature coefficient of open circuit voltage (Voc)
-0.23%/°C
 
Temperature coefficient of peak power (Pmax)
-0.29%/°C

Mechanical Parameters

Layout
108(6X18)
 
Junction box
Split junction box, IP68
 
 

Weight

21.6kg
 
Size
1800X1134X30mm
 
Packaging

36 pcs./pallet

216 pcs./20GP

864 pcs./40HC

936 pcs./13.5m FR

1296 pcs./17.5m FR

Electrical Performance Parameters (STC Test)

Module modelLR7-54HTHF-455MLR7-54HTHF-460MLR7-54HTHF-465MLR7-54HTHF-470MLR7-54HTHF-475M
Maximum power (Pmax/W)455460465470475
Open-circuit voltage (Voc/V)39.1539.3539.5539.7539.95
Short circuit current (Isc/A)14.7914.8614.9315.0015.07
Peak power voltage (Vmp/V)32.9833.1933.3933.5933.79
Peak power current (Imp/A)13.8013.8613.9313.9914.06

Electrical Performance Parameters (NOCT Test)

Module modelLR7-54HTHF-455MLR7-54HTHF-460MLR7-54HTHF-465MLR7-54HTHF-470MLR7-54HTHF-475M
Maximum power (Pmax/W)340.0343.7347.4351.2354.9
Open-circuit voltage (Voc/V)36.7636.9537.1337.3237.51
Short circuit current (Isc/A)11.9512.0012.0612.1212.17
Peak power voltage (Vmp/V)30.0930.2930.4730.6530.883
Peak power current (Imp/A)11.3011.3511.4111.4511.51

Mechanical Load Capacity

Maximum static load on the front (such as snow and wind)
5400Pa
 

Maximum static load on the back (such as wind)

2400Pa
 
Hail test
Diameter 25 mm, impact speed 23 m/s
 

Temperature Coefficient (STC test)

Temperature coefficient of short circuit current (Isc)
+0.050%/℃
 
Temperature coefficient of open circuit voltage (Voc)
-0.23%/°C
 
Temperature coefficient of peak power (Pmax)
-0.29%/°C

Product Introduction

Contact Us

LONGi offers professional consulting services, technical knowledge of PV power plant solutions, and full-life-cycle O&M capabilities.